Home > Buy Now > Massager > Other Massager > The First ONE Non-intrusive Hydrotherapy ---User's Manual
 


Mermaid Colon Hydrotherapy MFG. Co. Ltd
 
icon Mermaid Colon Hydrotherapy

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Mermaid Colon Hydrotherapy MFG. Co. Ltd
[China]
Address:
6/F, Guangqian Buliding, Bagua Road, Futian District, Shenzhen, China Shenzhen Guangdong 518023 China
Phone:
86-755-22367951
Contact name:
Strong Lau , Director
Inquire now










Mermaid Colon Hydrotherapy MFG. Co. Ltd



 
Mermaid Colon Hydrotherapy

The First ONE Non-intrusive Hydrotherapy ---User's Manual

Inquire now

The First ONE Non-intrusive  Hydrotherapy ---User's Manual

Click to enlarge image

 Model Number MMD01

Mermaid Colon Hydrotherapy MFG. Co. Ltd

Add: Rm302 3/F 69BLD, Baogang Rd, Luofu Dist Shenzhen, China.
Tel: +86-755-83094595 / 13713905143
Postal Code: 518029

Http://sound3w.en.ec21.com

Instructions for use
Mermaid Colon Hydrotherapy MFG. Co. Ltd


MMD01
Intestine Cleansing Hydrotherapeutic Equipment
Instructions for use
Be sure to read this manual before operating the product and keep it properly.


Announcement
MMD Intestine cleaning hydrotherapy apparatus is the patent product of Mermaid Colon Hydrotherapy MFG. Co. Ltd   The company will run the legal liabilities on any form of copy or forge!

Patent No.: 021105088.5
Patent no. for the new practical type: ZL02226864.2 ZL02226865.0
Appearance patent no.: ZL 02 3 24339.2

This product belongs to the Grade II national medical instrument product.

Registration certificate no. YYGX (Shi) Zi 2002 No. (2040039)
Manufacture license No. YYGX Manufacture license 20020572
Voluntary standards: Q/19MMT001-2001

"Mermaid' and ? ? are registered trademarks of Mermaid Colon Hydrotherapy MFG. Co. Ltd 


Content

1. Scope of application
Indication Suitable population Contraindication 1
2. About hydrotherapeutics 2
3. Complete machine
Body machine 3
Display Accessories 4
4. Precautions before use 5
5. Installation 6
6. How to use
1. Adjust water temperature 2. Hydrotherapeutics 7
Illustrative drawing 8
3. Position 4. Massage 9
7. Precautions in use 10
8. Precautions after use 11
9. About ozone water 11
10. Maintenance, frequently malfunction and debugging 12
11. Servicing 13
12. Performance index 13


Scope of application

◆ Indication
To clean out the old feces in the body and defecate;
To be used in pudendum and body surface cleansing to exert an efficacy of disinfection and sterilization.
◆ Suitable population
All kinds of population, especially for constipation patient (except children and patients with serious intestinal tract disease)
◆ Contraindication (People with following disease cannot use this product or complied with doctor's advice) serious artery or venous tumor, pregnancy, hemiplegy, stroke, Cardiac,cerebral, pneumonic insufficiency, megacolon, intestinal bleeding or perforation, colic, intestinal adhesion after abdominal operation, ileocecal valve resection, serious colon ulcer or obstruction, child under 12 years old
◆ Notice
Using under the direction of doctor is suggested;
This product should be used cautiously in underage people or elders above 60 years old with weak motor and self-control abilities.

Oesophagus

Liver Stomach


Transverse colon Descending colon

Ascending colon Small intestine

Ileum
Sigmoid flexure
Rectum

Illustration drawing for digestive system of human body

About hydrotherapeutic

The history of intestine cleansing in human beings is as long as the one of themselves. From Indian yoga to Traditional Chinese Medicine, they all have emphasized intestine cleansing and point out the cleansing method. E.Metchnikoff who is a pathologist and Nobel Prize gainer in medicine develop a school of his own?Autotoxicosis Theory of which the basic point of view is: The food accumulating in large intestine can transform into deleterious substances after corruption and cause autotoxicosis, disease as well as consenescence consequently.
A clean, strong and functional intestinal canal is the key to keep the best health. Without a timely elimination of waste and toxins in intestinal canal, disorder of metabolism and intestinal canal will take place to cause constipation, abdominal distension, obesity, dysmenorrhea or malnutrition as well as slowed metabolism and weak immunity from disease. Meanwhile, the distribution of toxins around the body may cause halitosis, cardiac&cerebral function failure, hidden sore, pigmented spot and depression etc. Just as we need to keep mouth clean through tooth brushing and gargle, we also need to guarantee body health through cleaning out the waste in our intestinal canal.
MMD intestine cleansing hydrotherapeutic equipment adopts non-intrusive method, filtrated pure water with constant temperature and pressure to clean colon. The principle for this method is that let filtrated water with constant temperature flow into body through anus to form a lubricative water layer between large intestine and feces quickly, by utilizing natural egesting mechanism of human body, the water can clear the bowels through cleaning the formed and old feces as well as toxins out of the body comfortably. It is a natural and safe method to get colon right without any toxic or side effect or producing any dependency. When compared with traditional intrusive equipment, this product can prevent disease through a natural method which has decreased diluting and softening step of feces, inserting procedure of tubes and the assistant procedure from nurse in inserting the tube so that the operation of the cleansing is more convenient, comfortable and economical in time.
MMD intestine cleansing hydrotherapeutic equipment is an innovative product with patent technique. It adopts globally originated non-intrusive hydrotherapeutic method which possesses many advantages such as compactness, taking effect quickly, being convenient in operation, avoiding pain for inserting and the patient can operate by himself without the help from others etc. The therapeutic procedure is more comfortable and safe.

Whole machine introduction

Body machine

Handle

Display screen

Warming button
Cooling button
Ozone button
Power
Jack


Water outlet

Water inlet


Obverse Inverse

Warming button is used to adjust water temperature through elevating water temperature.

Cooling button is used to adjust water temperature through decreasing water temperature.

Ozone control button is used to control the on-off of ozone generator from which the ozone water produced has disinfection and sterilization effect.

The power button is used to control the beginning and end of the whole procedure of hydrotherapy.



Whole machine introduction

Illustrate for information on display screen

Display for time of hydrotherapy


Display for ozone working state Display for heat-up grade


Display for real time water temperature

Switch on the water and electric power, after the hydrotherapeutic equipment begins to work normally, the information like the illustration will be displayed on screen of body machine.
Push the ?Warming? and ?Cooling? button to adjust the heating grade, the water temperature will elevate or decrease according to the change of heating grade.
The real time temperature of water coming out from hydrotherapeutic equipment will be displayed on the screen.
When ozone water is needed, push the ?ozone? button, design of continuous ascending air bubble will display on the screen. At this time, the water flowing out is ozone water.

Accessories

3. Switching connector for water inflow
1. Hydrotherapeutic tip
2. Outlet pipe


4. Power wire 5. Inlet pipe


Precaution before use

Important Precautions

1. Be sure to read this operating instruction before the initial use of the instrument.
2. The user should be proved to have no contraindication of the product before using it.
3、 The product should not be put under the environment with a temperature below 0°C, water vapor or high electromagnetic radiation.
4、 The hydrotherapeutic function of the product is only suitable to human body. The application to any biomass for hydrotherapy other than human being is prohibited.


Precautions

1. Switch on the water source before switching on electrical source. Check up if there were any leakage of water on each interface.
2. The instrument should not be used if the water source goes badly or presents a great deal of mud, sand or dirt, and the water pressure is unstable and <0.3Mpa.
3. The instrument should not be used if the problems occur to local electric source such as, the voltage becomes high or low suddenly.
4. This is an electrical appliance and its crust has some waterproof performance. Its circuit is also waterproof. However irrigating or immersing it with water should be avoided to prevent malfunction and risk.
5. If the water temperature is too high or low in use, for example the water feels too hot or cold while the temperature displayed is 30˚C shut the instrument at once. On the same time, invite special maintenance man to repair it.
6. The complete set of heating element, circuit and ozone genitor is all durable and high performance materials in chassis. However, in order to guarantee the safety of the complete machine, the internal accessories should not be taken down or changed optionally to avoid accident or danger because of the fuses with a high susceptibility installed in both jack and chassis for preventing overloading or creepage.
7. Children?s playing with it or pushily tearing down should be avoided.

Precaution before use

Important precautions

1. Be sure that the voltage and frequency of AC power supply connected with hydrotherapeutic instrument complied with the requirement (220V士10%, 50Hz士10%) and has enough current capacity (≥15A).
2. The only method to cut the power supply of hydrotherapeutic instrument completely is taking off the plug of power supply.
3. Be sure that the installing place has no seeper or pouring of water.

Placement of hydrotherapeutic apparatus
You may remove the instrument by fasten its handle. The instrument and its accessories should be placed according following guide:
1. You had better use it in toilet.
2. The surface of the ground or table (1 meter from the ground) where the instrument being placed on should be stable and smooth and will not be poured by water.
3. The interface of power wire should not be nipped between metope and other objects.

Please see following drawing:
1. Connect one end of the inlet pipe with tap (or use manual switch tie-in) tightly and connect the other end of inlet pipe with rear inlet of the instrument.
2. Connect one end of the outlet pipe with hydrotherapeutic nozzle and spin the screw cap of the other end with rear inlet of the instrument.
3. Connect the power wire with jack on the rear of instrument firmly and connect the other end with earthing jack or multiple-holed jack.


Figure for the installation
of hydrotherapeutic instrument


How to use

1、 Adjust water temperature and pressure
First, please connect the inlet and outlet pipes of the hydrotherapeutic instrument according to installation figure. Switch on the tap and turn on the power supply. The indicator light should light up at this time. Push the ?Start? button, all of the indicator lights will light up and the Mermaid trademark, the pre-set hydrotherapeutic time and real time water temperature will be displayed. At the same time, source water was infused from tap to the instrument. The hydrotherapeutic time preset is for 40 minutes initially. Now you enter the time setting pattern, the hydrotherapeutic time can be increased or decreased for 5 minutes at each pushing of the ?warming? or ?cooling? button.
When the water flows out of the nozzle, observe the height of water column and adjust the tap to keep the height in 3-8cm;
After setting the time and water column, push ?START? again to enter hydrotherapy pattern. The controller begins to heat the water and control the water temperature. The time counter begins to count down.
After waiting for 2 minutes, the reading become stable and the current outlet water temperature is the one produced through the work of instrument with a default power (Grade 5). According to personal like, adjust the water temperature in the range of 30-35°C, please see fig. S-3 ( water temperature around 35°C is suggested).

**Special notice:
1、 The correct way to know the water temperature is to read the figure after it has been stable for at least 5 second.
2、 Be avoid to change the temperature grade greatly.
3、 2 minutes or more is needed to adjust the water temperature to a suitable level.
4、 The instrument could not work if the temperature of source water exceeded 38˚C.

2. Start hydrotherapy
After adjust the water temperature to a suitable one, put off the lower clothes and pour the water from the nozzle of instrument on the back of hand or body surface to try if the water temperature is suitable. Then sit down, stand or squat before closestool and relax yourself. Hold the bottom of hydrotherapeutic nozzle in hand and put the nozzle on the anus from in front or behind the body. Let the nozzle adhere anus gently and contract sphincter anal gently at the same time to let the filtrated, purified and warmed water flow into colon slowly. Several or several tens of seconds later, remove the nozzle quickly when having a intense desire for egesting. Defecate naturally on closestool. The feeling is similar to diarrhea. After defecating, put the nozzle on anus again and let water flow into colon to cause defecating again. Cleaning the colon completely which is 1.5 meters long needs infusing or draining water repeatedly for more than ten or twenty times and 20-40 minutes. After the completion of hydrotherapy or rinsing, please push ?START? button first to shut body machine, and then shut the tap, disconnect power wire and pipes, at last, wash the nozzle clean and put it with body machine and pipes in a safe place to avoid high temperature, insolation and wet.

How to use


Warming
Cooling


S-4 Sketch map for operation

How to use

3.Hydrotherapeutic postures:
There are several postures such as sitting, standing; squatting and lying can be adopted in hydrotherapy. You can choose according to personal situation.
1. Standing (two kinds)
A. Relax and slightly bend your two legs, spraddle, raise your buttocks backward slightly, put the gravity center of your body on one foot with other foot point floor anterior sole. Also, you can put the gravity center of your body between your two legs. Put the nozzle on anus gently and contract anus slightly. Remove the nozzle until you feel abdominal distension (desiring to defecate in rectum) and defecate.
B. Stand with the two legs tandem, put the nozzle on anus gently and contract anus slightly. Your lower abdomen can be put forward slightly. Even you can go about if affusing well.
2. Sitting posture: This posture can be divided into anterior and posterior hydrotherapies. The former is more suitable for female and the later for male. Pay attention to relax during hydrotherapy. Remove the nozzle once you feel abdominal distension. Avoid distending the colon for a long time purposely to prevent any harm to your body.
3. Lying posture: Detach your two legs and put the nozzle on anus. The operation is the same as above statement. But pay attention that the assistant person and the user should cooperate closely and be sure to remind that the nozzle cannot be inserted into the anus of the user vigorously. Keeping it close to anus is enough. Because of the small gap between the nozzle and anus, a small quantity of water leakage is normal and safe. In addition, the operator also needs to think over the disposition of discharged fecal liquid and feces in advance such as the selection of locus and cleaning method.
4. Squat posture: You can refer to the operation mentioned in the section of sitting or standing posture.

4. Hydrotherapeutic massage:
Infuse water through nozzle with one hand and press your abdomen gently with the other hand through let the hand go around and around widdershins. Perform affusion and drain for about twenty times: affusion and massage on lower abdomen under navel for 1-6 times, affusion and massage on left abdomen on left of navel for the 6-13 times and massage on both parts of abdomen for the 13-20 times. If feel abdomimal pain during hydrotherapy, squat and let the feces discharged, and then start hydrotherapy again. Keep in mind that relaxing is the best state for hydrotherapy.

Precaution during use:
1. Intestinal hydrotherapy with ozone is prohibited.
2. Be sure that the water flow is consecutive and controlling the water flow through shutting off is prohibited.
3. Abdominal pain and distension are normal reactions in hydrotherapy. However the operation must be stopped at once if the ache or distension is beyond endurance.
4. The operation should be stopped at once the water feels too hot or cold while the temperature displayed is in the range of 28-35˚C



1. Keep relaxed during the process of treatment; the more natural and relaxed, the more comfortable.
2. In case of misoperations during treatment (such as obstacles or water flow block), the machine will close down and give alarm automatically. The water flow will be cut off suddenly and resume after a few seconds. Such phenomenon is safe and normal. After the water temperature reaches 28-35?C, you can continue.
3. The water temperature between 28-35°C is the safe range for treatment.
4. Erect the hydropathical nozzle, the height of water column within 3-8cm is the proper hydraulic pressure.
5. While irrigating water into the large intestine, massage the abdomen softly with the other hand. Experience deep distension before excrete. Sit on closestool for 2-3 minutes after treatment to excrete the remaining water in the abdominal cavity.
6. In case of first application, water injection may be unsmooth. It is very simple as long as you grasp the skill. When putting the nozzle in the entrance of anus, contract anus and stick the abdomen out as if the hind limb movement of stretching. The most important, of course, is to relax. It is easy to grasp soon.
7. In case the temperature of water output exceeds 36°C, the machine will adjust power and reduce temperature automatically. You may need to readjust heating grades. If the temperature exceeds 38°C for 10 seconds, the machine will close down automatically to guarantee safety.



Precautions after use



1. Power and water supply must be cut off after use. The machine and accessories must be dried and kept in cool and dry place;
2. The hydropathical nozzle is for private use. Do not share nozzle or use one spray for long time (over 2 months) to avoid cross infection.



1. We suggest family users take hydrotherapy before bathing every evening. The treatment is helpful to improve sleeping quality;
2. After treatment, you may feel abdominal pain or distension for a while; some one may even have the symptom of light diarrhea. They are normal reaction of hydrotherapy and mostly due to nervous emotion for the first application. Keep relaxed and get used to it for a period of time, such symptoms will disappear;
3. The filter, water inlet pipe and outlet pipe must be replaced once every 6 months;
4. Replenish lactic acid bacteria (e.g. drink yoghourt) appropriately after treatment to promote reproduction and growth of probiotic bacteria in the intestines;
5. Don?t take repeat treatments in one day. We suggest make treatment schedule according to individual situations.

About ozone water
The machine has an ozone generating device inside. The generated ozone can be used to wash body surface or external genitalia with disinfectant function; it can also be used to sterilize nozzle and pipes after treatment or indoor air; Don?t release ozone during treatment, since ozone can do harm to probiotic bacteria in the intestines.
When the buzzer gives continuous alarm to inform treatment conclusion, or pressing START button to adjust timer to zero, press ?Ozone? button, the screen will display rising air bubbles (see S-6), which refers to the output of ozone water.

**Important prompt: When using ozone water, there will be light fishy smell in the air. It is normal phenomenon due to the increase of ozone.

Maintenance

There is no part for user?s adjustment inside the machine. Don?t open the machine to avoid human failure or electric shock.
Since the internal structure is very complicated and compact, maintenance work must be performed by professionals with special equipment, so as to guarantee that the repaired machine can reach standard requirements. Any machine repaired outside of our company (including by the user) will be deprived of free maintenance service. The company will reserve the right to investigation for any result thus caused. Please contact the Customer Service Department in case of any exception. Don?t and it?s unnecessary to disassemble the machine.
Mop up the machine case with dry towel after use; store the nozzle and pipes after dry up; keep in cool and dry place with power plug switch off.

**Special attention: cut off power and pull out plug before cleaning and maintenance.


Troubleshooting Guide

Symptom Cause Solution
Power light and screen do not light 1. Power supply is not connected normally.
2. Electric leakage protection switch is off. Check if the connection of power plug and electric leakage protection switch is correct and in normal status.
There is no water output 1. Power supply is not connected normally.
2. Water faucet is not opened.
3. No water supply. 1. Check if the connection of power plug and electric leakage protection switch is correct and in normal status.
2. Check source water supply.
The water output temperature does not rise 1. No display of temperature grades.
2 Too small current.
1. Press the Start button once again.
2. Adjust water faucet to make the height of water column within 3-8cm when erect the hydropathical nozzle.
Automatic closedown Temperature of source or output water exceeds 38°C for long time. Switch off the machine and restart up when the temperature of source water lowers down.
Screen display skips 1. There is strong electromagnetic interference.
2. The operating environment is too humid or has vapor.
3. Water entered into the machine and has influence on precise components. 1. Turn off the source of interference.
2. Improve operating environment
3. Dry up the machine. Put it in draughty place for a period of time before use.



Symptom Cause Solution
Water-break during operation 1. No water supply.
2. Water outlet pipe is blocked (with alarm) 1. Turn off the machine immediately.
2. Move the nozzle away and return to normal.
No ozone produced 1 Didn?t operate as the ozone operation flow.
2. Outlet pipe is higher than the machine 1. Operate as the ozone operation flow
2. Lower the outlet pipe to the position lowers than the machine water exit.
Unstable temperature and sometimes tripping 1. Unstable hydraulic pressure
2. The machine is installed too high. 1. Stabilize hydraulic pressure.
2. Lower installation height (80-100cm)
Automatic power off when lower the water temperature from over 30°C to 28°C 1. Unstable hydraulic pressure
2. A protection system to avoid cool water being injected into the body. 1. Stabilize hydraulic pressure.
2. Restart up.
Close down when the temperature rises to 35°C; and temperature lowers down and automatically close down after restart-up A protection system to avoid scald. Press Start button when restart up the machine; repress it when the temperature display is less than 30°C.
Automatic close down when the display is 40°C 1. A protection system. The normal temperature should be within 30°C~35°C (±2); it will close down automatically in case of higher temperature.
2. Too low hydraulic pressure 1. Restart up
2. Adjust hydraulic pressure (water column 3-8cm)
Temperature below 35°C in winter Temperature of source water is lower than 5°C. Adjust inlet pressure and keep it stable. The water column should be about 3cm high.
Display L.H.E L: Inlet water is lower than 10°C;
H: Outlet water is higher than 39°C;
E: Operation error. 1. Heat to over 10°C, then the display will be normal;
2. Close down automatically due to too high temperature. Restart up.
3. Restart up and return to normal automatically.
Water leakage from the stabilizer Installation of inlet pipe port and machine exit is incorrect. Reinstall the pipe port.



Notice for Guarantee

1. For any defect, in the judgment of our technician, cased under normal use, we are responsible for repairing or replacing part. Warranty service will be performed free of charge within one year from date of purchase
2. Free guarantee service excludes accessories, consumable articles, power lines, manuals and wrapping material.
3. Free service will not be provided if:
① It has been explicitly or implicitly modified, tamped with or altered or repaired in anyway by persons other than technicians of our company;
② It has been damaged through misuse, negligence, accident;
③ It has been damaged by repair, modification, and disassemble in places otherwise our company;
④ It has been damaged by force majeure such as natural calamities, fire, earthquake, etc. After purchase;
⑤ It has been damaged by connecting other equipment to the machine.
4. Our company will not undertake the responsibility for the default of other equipments directly or indirectly caused by the default of this product
5. If the protective label is found damaged; the free guarantee service is cancelled at the same time.
6. Please contact the dealer/supplier or after sales service department of our company for the details of maintenance expiring the guarantee period.
Life time: 5 years
Term of service: 1 year

Performance index
Power supply: AC220V士10% 50Hz士10% Overall power: 2000W
Working noise: ≤50dB Filter precision: 5µm
Pilot switch for water pressure: ≥ 10Kpa Ambient temperature: 4-38°C
Ozone generating capacity: 200一300mg/h Specification: 380?180?380mm
Package size: 480?340?480mm Weight: 10kg

*Provision of technical data*
The technical data with respect to the product (circuit diagram, components and parts list, etc.) can only be provided to the qualified professional personnel after the technical training of our company. Apologize for any inconvenience in this may cause.
* The technical parameters are subject to change due to the constant improvement of technology without otherwise notice.
*Mermaid Colon Hydrotherapy MFG. Co. Ltd . is in the possession of the final right to interpret this instructions for use.